Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13710001
| No.13710001
- Product Categories
- Friendly Links
| Information Name: | Guangzhou Shiko supply Aloka SSD-5500 circuit board assembly SAP-5000-01-07 |
| Published: | 2015-05-14 |
| Validity: | 30 |
| Specifications: | |
| Quantity: | 44.00 |
| Price Description: | |
| Detailed Product Description: | Address: Guangdong Province, Tianhe District, Guangzhou Dongpu Huangcun Avenue Fuyuan Road on the 5th Chenhui business center D508 Zip: 510660 Tel: (020) 22191289 Fax: (020) 2219129024 hours Tel: 4000-813-989 Contact : Lujing Li 13535278369 QQ: 3172657611 Email: 800026893@b.qq.com supply COVER: REAR TOP circuit board assembly SAP-5000-01-07 Aloka SSD-5500 colorful, unique applications and analysis capabilities 1, profiles of blood: ALOKA has developed a unique way of quantitative analysis of blood for a variety of round blood vessels and tortuous vessels detected, providing instantaneous blood flow. 2, the Doppler spectrum automatic tracking tracings: doctors convenient and simple to operate means of measurement. A variety of special analytical methods unique B-TDI, M-TDI, PF-TD and PW-TDI, etc.: 3, tissue Doppler and quantitative analysis techniques (TDI). You can focus on regional myocardial velocities, instantaneous velocity and acceleration track recording and analysis. TDI has become an important cardiac functional assessment technology to accurately analyze high-amplitude, low-frequency Doppler shift and by color coding shows the velocity of myocardial tissue in real time. TDI can be non-invasive diagnosis of myocardial systolic and diastolic velocity, were left ventricular systolic, diastolic function evaluation, especially in the evaluation of diastolic function, TDI can be involved in the contractile function of the myocardium movement before patients receive low early diagnosis. Aloka SSD-5500 the e-TDI with high-speed tissue Doppler analysis, can accurately calculate the speed of movement of the wall intima to evaluate the status of left ventricular segmental movement, access to quality Doppler information , the measured parameter value speed, average speed and instant acceleration, precise analysis of cardiac function opens the door. 4, KI & A-SMA :( endocardial tracings and cardiac motion analysis technology to automatically partition) cardiac wall motion of the tool developed by the ALOKA unique real-time quantitative analysis. In whole or in part on ventricular wall motion cycle of interest in color gradation qualitative analysis, quantitative but also a histogram and a linear way of local lesions wall quantitative analysis. Is another contribution to the diagnosis and differential diagnosis of ultrasound ALOKA companies use new technology to help patients with coronary artery disease and myocardial infarction made. 5. Echocardiography stress test echocardiography stress test with different load methods, evaluation of normal subjects and patients with various heart diseases cardiac function, coronary flow reserve capacity to determine the extent of myocardial ischemia and myocardial viability for patients interventional revascularization therapy provides very useful way to check valuable information. According to the experimental nature of its three categories: 1) dynamic load echocardiography 2) Static stress echocardiography test 3) pharmacological stress echocardiography test load ALOKA Ultrasound biggest advantage is that it can and ALOKA exclusive myocardial automatic partitioning Motion Analysis A-SMA application technologies more effectively identify and determine the status of the heart muscle activity and movement. 6, full M mode (FAM): ALOKA's proprietary real-time dynamic in machine acquisition, 360 ° rotation, arbitrarily changing the angle of the M-curve tracings. She broke the traditional M mode sampling limitations, improve the accuracy of echocardiography detected value, an increase of regional wall motion can be observed; the most remarkable is the ultrasound the doctor: ALOKA create the world's first application of up to three comprehensive sampling line M mode and can be completed in real-time or frozen, in clinical more practical and more convenient. 7, BETA (backscatter energy time analysis): You can analyze characteristics of myocardial tissue, ALOKA's BETA technology to increase the analysis M mode, the introduction of the time value of fixed levy is more suitable for the analysis of myocardial tissue. 8, cardiac function index (IMP or TEI): Use time Doppler spectrum measured parameter value on the overall function of the heart of a comprehensive evaluation and analysis, but also increases the overall function of the right heart analysis, Tei index reflects ventricular systolic and overall diastolic function. The method is suitable for left and right ventricular function and fetal cardiac function evaluation. ALOKA of ultrasound can be this efficient detection and analysis of cardiac function in machine operation is simple, small interfering factors, reproducible definition ventricular Tei index Isovolumic (ICT) and isovolumic relaxation (IRT) of and the ratio of ventricular ejection time (ET), ie Tei index = (ICT + IRT) / ET Ventricular inflow Ventricular outflow T = ICT + IRT ET = ab b ab ICT Isovolumic Contraction Time IRT:? Isovolumic Relaxation Time ET: Ejection Time 9, three-dimensional imaging technology: real time 3D surface imaging mode ALOKA provided probe the appearance of simple, easy to use, fast imaging; ALOKA company also has a variety of three-dimensional reconstruction mode selection (surface vessels and slice mode, etc.). You can achieve real-time three-dimensional imaging in the abdomen and the cavity. 10. E-TRACKIN eTRACKING quantitative analysis techniques: ALOKA exclusive launch eTRACKING quantitative analysis, by measuring the carotid and femoral pulse wave velocity indirectly assess the extent of atherosclerosis thrombosis between two points in the fast formation of thrombus or plaque Prior to the analysis of vascular stiffness. The technology consists of three analytical parameters: Ep- pressure strain elastic modulus (representing arterial stiffness) β- stiffness parameters (representing arterial stiffness) AC- arterial compliance (on behalf of vascular compliance) which can be applied: 1) early detection of atherosclerosis in patients 2) Before the arterial wall thickening and the formation of atherosclerotic plaque, found that the likelihood of atherosclerosis mark block endothelial cell injury nonorganic damage wall thickening 3) Cerebral census: β values ??can also be used to discharge the patient census infarction, and in this regard it must first invasive examination methods in CT, angiography; β value is also expected after treatment for drug efficacy and risk factors were evaluated after surgery ; in the physical examination, healthy people can achieve their expected vascular age, so you can guide them to improve lifestyle, such as diet, physical exercise, healthy people to avoid the development of atherosclerosis. 11, rich reporting analysis. Built heart, peripheral vascular, gynecology and urology reports. 12. Built-in image management and integration of enhanced reanalysis enhanced processing system e-DMS Aloka newly developed built-in e-DMS integrated management system, such as high speed acquisition: RF, linear signal of the original image data, and stored digitally. By e-DMS, doctors can easily image permanently saved, you can use the printer to print, it can also be connected directly with a PC. At the same time, e-DMS is also compatible DICOM format. You can easily manage patient data and images via E-DMS, but also for a variety of on-line analysis, quantitative tissue analysis such as Doppler TDI, intima echo tracking analysis, endocardial tracings KI and myocardial motion analysis phase partitioning process A-SMA, wall motion analysis STRESS-ECHO, the blood flow profile analysis Flow Profile and so on, to bring great convenience for doctors. |
Admin>>>
You are the 21516 visitor
Copyright © GuangDong ICP No. 10089450, Guangzhou Shiko medical equipment maintenance Services Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 21516 visitor
Copyright © GuangDong ICP No. 10089450, Guangzhou Shiko medical equipment maintenance Services Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

